Furnace & heating
AC repair
Heat pumps
Ductless mini splits
Carrier
Trane
GoodmanSeasonal tune-up and full diagnostic on your Carrier, Trane, or Goodman system - readings shown to you before any repair is proposed
Diagnosis first, numbers second - you approve the repair price before a single part goes in.
Get your free estimateLennox Mini-Split Installation: The San Antonio Owner’s Guide
If you have a Lennox mini-split that’s dead, leaking, or never worked right, we can replace it. A new Lennox mini-split installation in San Antonio typically runs $3,500 to $7,500 installed, depending on the BTU capacity, number of indoor heads, and how much line set and electrical work the job needs. We stock common Lennox-compatible parts on our trucks and can often have a failed system diagnosed the same day you call.
Most homeowners discover a failed mini-split installation the hard way: the unit runs constantly and the room never cools, or the outdoor condenser makes a rattling sound, or water starts dripping from the indoor head onto the floor. Sometimes it’s a control board. Sometimes it’s a failed compressor. Sometimes the original install was wrong from day one: undersized line set, kinked copper, a bad flare connection that lost refrigerant slowly over two San Antonio summers. Whatever the cause, you want to know three things: what’s actually broken, what it costs to fix versus replace, and who can do the work without tearing up the house.
Tell me what the house is doing, and I will tell you what it needs – no guesswork, no upsell.
That’s how Luis Serrano runs every Lennox mini-split installation call. We diagnose first, hand you a written price before any work starts, and we don’t push a replacement when a $300 repair fixes the problem.
Which Lennox Models This Applies To
Lennox mini-splits fall into two main lines: the MLA and MPB single-zone series, and the multi-zone MPA and MPC systems that run two to five indoor heads off one outdoor condenser. Capacities run from 9,000 BTU (a single bedroom or small office) to 48,000 BTU (a large open living area or small commercial space). The model number on the outdoor unit’s side label tells you what you have: look for a tag starting with “MLA,” “MPA,” “MPC,” or “MPB,” followed by the BTU rating and a voltage code. The indoor heads carry matching labels on the underside of the front cover.
The practical gotcha with Lennox mini-splits in San Antonio is voltage. Smaller 9K and 12K units are often 115V, while 18K and up are usually 208/230V. If you’re moving a head or replacing an outdoor unit, the existing electrical circuit has to match the new equipment’s nameplate voltage. We check this before we order anything. Another compatibility issue: Lennox has used both traditional R-410A refrigerant and, on newer models, R-32. You can’t mix them, and you can’t flush one and reuse the existing line set without verifying the line set is sized and rated for the new refrigerant. These are the details that turn a “simple swap” into a legitimate installation job.
For replacement parts, we offer Lennox OEM components and quality aftermarket alternatives from brands like Supco and Mars when they meet or exceed the original spec. We’ll tell you the difference in price and warranty honestly before you choose. Because we’re an independent service provider – meaning we’re not affiliated with Lennox corporate – we’re free to recommend the part that actually makes sense for your system and budget, not the one a brand rep wants us to push.
Styles & brands we work with







Signs Your Lennox Mini-Split Installation Is Failing
- The system runs but barely cools. This usually points to low refrigerant from a slow leak at a flare connection, or a condenser coil clogged with San Antonio pollen and cottonwood debris. The compressor keeps working harder than it should, which shortens its life.
- Water drips from the indoor head onto the floor or wall. A blocked condensate drain line or a cracked drain pan is the culprit. Left alone in a humid San Antonio August, this becomes drywall damage and mold behind the paint.
- The outdoor unit makes a loud buzz and then shuts off. This is often a failing capacitor or a compressor that’s locked up. If it’s the capacitor, that’s a same-day fix. If it’s the compressor on an older unit, replacement math starts to compete with a new system.
- One indoor head works while the others blow warm air. On multi-zone MPA/MPC systems, this can be a failed electronic expansion valve on one head, or a refrigerant distribution issue at the branch box. It’s not a settings problem; it’s a real component failure.
- Strange smells when the system first kicks on. A sour smell from the indoor head usually means microbial growth on the blower wheel and coil. It’s cleanable, but it’s a sign the system has been running with poor drainage or long gaps between filter cleanings.
See the difference
Before
After
Before
After
Before
AfterReplacement Cost & What’s Included
A full Lennox mini-split installation in San Antonio runs $3,500 to $7,500 for a typical single-zone or two-zone system. That price includes the outdoor condenser, one or more indoor wall heads, new line set, a pad or wall bracket for the condenser, a new dedicated electrical circuit where required, condensate drainage, and a full system evacuation, leak test, and startup charge. For a multi-zone system with four or five heads, expect the higher end of that range and possibly a bit beyond, depending on line set lengths and wall penetrations.
The range comes from three things: capacity, complexity, and condition of the existing electrical setup. A 9,000 BTU single-head replacement where the old electrical circuit is in good shape sits near the bottom of the range. A 24,000 BTU system with new disconnect, new breaker, a long line set run through an attic, and a wall bracket on a stucco exterior sits near the top. We’ll measure, inspect, and give you a written fixed price before any work begins. That price won’t change unless we find something structural no one could have seen from the outside – and we’ll explain it before we touch it.
DIY or Call Us?
There’s one thing you can safely check yourself: the return air filter on the indoor head. Pop the front cover, slide out the filter, and rinse it if it’s clogged with dust. That’s a maintenance item, and a dirty filter does mimic some failure symptoms. Beyond that, this is not a DIY repair. Mini-splits run 208-240 volts at the outdoor unit and the line connections. That’s enough to kill, and it’s why we recommend a trained professional for anything beyond filter cleaning. The electrical panel, the refrigerant circuit, and the high-tension components inside the condenser are not homeowner territory.
Refrigerant handling requires an EPA certification. Improper flare connections leak, and an undercharged system destroys its own compressor. We’ve replaced more than a few compressors in San Antonio homes where a handyman “install” saved a few hundred dollars up front and cost four thousand within two years. If you want an honest read on whether your system is repairable or needs replacement, call (254) 271-2545 and one of our technicians will inspect it and give you a straight answer with a written price.
FAQs
A properly installed Lennox mini-split system should last 12 to 15 years in San Antonio’s climate, with the compressor typically being the first major component to fail. Harsh summer heat and hard run hours shorten that compared to coastal or northern installs, but a clean install with proper refrigerant charge and clean condensate drainage buys you years of extra life. Call (254) 271-2545 if you want us to assess the remaining life on your current system.
Many failures can be repaired, especially if the issue is a capacitor, control board, fan motor, or a refrigerant leak at an accessible flare connection. If the compressor has failed or the system is over 10 years old and leaking in multiple places, replacement usually makes more financial sense. We’ll show you both numbers and let you decide, with a written price for each path.
A straightforward single-zone replacement in San Antonio typically takes 4 to 6 hours, including evacuation and startup. A multi-zone system with new electrical and multiple line set runs can take a full day or two. We’ll give you a clear timeline before we start, and we’ll protect your floors and walkways while we work.
We keep common Lennox-compatible capacitors, boards, fan motors, and line set components on our trucks, and we can source OEM Lennox parts quickly when a specific model calls for them. We also stock parts for Carrier and Trane systems. For most failures we diagnose the same day, and we can often complete the repair on the first visit.
Written by Luis Serrano, Owner, Meadowsweet Heating and Air San Antonio at Meadowsweet Heating and Air San Antonio, serving San Antonio and nearby areas.